Jacksonville Electrician Logs

80319105

Date: April 10, 2026
Zip Code: 32257
City: Jacksonville

Electrician Notes

Electrical Panel Replacement:
1.   Federal Pacific  panels were very popular in the 80s and 90s. Some of this brand of panel have been known to overheat and could  cause a fire. A circuit breaker is designed to trip during an overload or short circuit, thereby cutting off the flow of power and preventing a fire. If the breaker doesn’t trip, the increasing current can cause the  wires to overheat and possibly ignite. Federal Pacific panels have overheated under normal circumstances.  We would recommend changing the panel.
2.   Provide and install (1) new 200amp main breaker, 42-space Square D panel, replacing the  existing Federal Pacific panels as follows:

·          42 space  120/240
·          200amp Main  Breaker
·          (3) 2p 30amp  breakers
·          (6) 1p 20amp  breakers
·          (1) 2p 20amp  GFCI protected breaker
·          (5) 1p 15amp  breaker
·          (2) 2p 50amp  breakers

3.     Shut down of electrical service required while work is being performed, approximately one day.
4.     Provide and install (2) new white Decora GFCI receptacles in Kitchen.
5.     Provide and install (1) new white Decora GFCI receptacle on front porch.
6.     No additional  troubleshooting included.
7.     No repair/replacement of wooden shelving in front of panel.
8.     Work to be completed during NORMAL business hours, Monday-Friday.
9.     No painting or patching included.
10.   Disposal of old materials included.
11.   Permit  included.