Electrical Panel Replacement:
1. Federal Pacific panels were very popular in the 80s and 90s. Some of this brand of panel have been known to overheat and could cause a fire. A circuit breaker is designed to trip during an overload or short circuit, thereby cutting off the flow of power and preventing a fire. If the breaker doesn’t trip, the increasing current can cause the wires to overheat and possibly ignite. Federal Pacific panels have overheated under normal circumstances. We would recommend changing the panel.
2. Provide and install (1) new 200amp main breaker, 42-space Square D panel, replacing the existing Federal Pacific panels as follows:
· 42 space 120/240
· 200amp Main Breaker
· (3) 2p 30amp breakers
· (6) 1p 20amp breakers
· (1) 2p 20amp GFCI protected breaker
· (5) 1p 15amp breaker
· (2) 2p 50amp breakers
3. Shut down of electrical service required while work is being performed, approximately one day.
4. Provide and install (2) new white Decora GFCI receptacles in Kitchen.
5. Provide and install (1) new white Decora GFCI receptacle on front porch.
6. No additional troubleshooting included.
7. No repair/replacement of wooden shelving in front of panel.
8. Work to be completed during NORMAL business hours, Monday-Friday.
9. No painting or patching included.
10. Disposal of old materials included.
11. Permit included.