Electrician Notes
Wire new enclosure and summer kitchen to customer specification. Wire for and install 60A NEM3R sub-panel next to pool equipment to service summer kitchen and all new circuits. (2) 120 V 20-amp dedicated circuit to summer kitchen with two outlets on top and 1 under for fridge and igniter. Wire for install quad outlet for TV and TV components on wall of summer kitchen. Wire for install 2 customer provided ceiling fans on fan beam (no switch). Wire for install 120 V 20-amp dedicated circuit for summer kitchen island with one outlet on each side and one outlet underneath for a customer use (Customer or Impact will get or provide conduit and trench to island). Wire for install 30-amp 240 V circuit for heater. Any additional work will be charged and billed at time and materials.